Peacefair Pzem-051 Manual -
| Action | Display Mode | Result | | :--- | :--- | :--- | | | Normal (Power) | Cycles display: Power (W) → Voltage (V) → Current (A) → Energy (kWh) | | Long Press (5 sec) | Energy (kWh) | Resets accumulated Energy to Zero | | Short Tap (0.5 sec) | Power (W) | Toggles Backlight ON/OFF (depending on version) | | Long Press + Short Tap | Voltage (V) | Enters calibration mode (Factory use only. Do not use ) |
If you own a , keep the small paper manual that came with it – Peacefair’s model numbers and pinouts sometimes differ between production batches. For the most accurate wiring, locate the printed label on the shunt itself: it will state “100A 75mV”. Always connect the meter’s auxiliary power first before connecting the high-current circuit. peacefair pzem-051 manual