Elstat Ems 55 Advanced User Manual New [repack] Instant

Occurs during closing hours. Lights are off , the evaporator fan cycles, and the temperature is allowed to rise to a more economical set point (approx. 50°F) to save power.

| Code | Description | Typical Range | Factory Default | Notes | | :--- | :--- | :--- | :--- | :--- | | | Set Point | -50°C to +50°C | 3°C | The target temperature for the cabinet. | | C1 / HY | Differential (Hysteresis) | 1°C to 15°C | 2°C | The gap between cut-in and cut-out. If Set Point is 3°C and Diff is 2°C, the compressor turns off at 3°C and back on at 5°C (3+2). | | C2 / Od | Output Delay | 0 to 15 min | 2 min | Safety delay to protect the compressor from short-cycling after power loss or cut-out. | | C3 / Ls | Minimum Set Point Limit | - | -50°C | Prevents the user from setting the temp too low. | | C4 / HS | Maximum Set Point Limit | - | 50°C | Prevents the user from setting the temp too high. | | dF / d0 | Defrost Type | 0, 1, 2 | 1 | 0 = Off, 1 = Electric, 2 = Hot Gas. | | d1 | Defrost Interval | 0 to 24 hrs | 6 hrs | How often a defrost cycle initiates. | | d2 | Defrost Duration | 0 to 60 min | 20 min | Maximum time allowed for a defrost cycle. | | d3 | Drip Time | 0 to 15 min | 5 min | Time allowed for water to drain after defrost before fans/compressor restart. | | Fn / F0 | Fan Mode | 0 or 1 | 1 | 0 = Fans run with compressor; 1 = Fans run continuously. | | F1 | Fan Stop Temp | - | 2°C | Stops fans if evaporator temp drops below this point (prevents freezing). | elstat ems 55 advanced user manual new

Uses both an appliance sensor (-15°C to +23.5°C) and a condenser sensor (+50°C to +125°C) for higher accuracy. combustioncontrols.pk The "Key Dance" (Configuration Menu) Occurs during closing hours

For regulated industries (GxP, HACCP, Joint Commission), the manual provides a checklist for using the EMS 55 as a primary monitoring device. | Code | Description | Typical Range |